Web Site Index and Navigation Center

.45 ACP Remington 185gr +P Golden Saber JHP (Glock 30)

.45 ACP Remington 185gr +P Golden Saber Brass JHP
Product Number: GS45APC, Lot Number: K 26 WA2202
Test Date: 12/99
Test Weapon: Glock 30, 3.8" bbl  
Bare Gelatin   Denim Covered Gelatin
Gelatin Calibration: 10.2cm @ 615 fps Gelatin Calibration: 10.2cm @ 616 fps
Shot # Velocity
Feet/Sec
Penetration
Inches
Expansion Shot # Velocity
Feet/Sec
Penetration
Inches
Expansion
1 1033 14.6 .68 1 1050 15.3 .64
2 1045 13.7 .70 2 1034 15.7 .67
3 1047 13.7 .69 3 1016 18+ NR
4 1030 13.9 .68 4 1038 18+ NR
5 1011 13.5 .67 5 1037 16.2 .63
Avg. 1033 13.9 .68 Avg. 1035 See Remarks See Remarks
Corrected 13.3   Corrected See Remarks  
Remarks:
Gelatin calibration corrected to 9.7cm in accordance with: "Figure 5-2, Velocity Variation Correction to Measured BB Penetration Depth." Bullet Penetration, MacPherson, Duncan, Ballistic Publications, El Segundo, CA, 1994, p. 84.

Five shot average penetration depth corrected to 13.3 inches in accordance with: MacPherson, Duncan: "A Simplified Penetration Depth Correction for Data Taken in Non-standard Gelatin." Wound Ballistics Review 2(2); pp. 41-45, 1995.

Remarks:
Gelatin calibration corrected to 9.7cm in accordance with: "Figure 5-2, Velocity Variation Correction to Measured BB Penetration Depth." Bullet Penetration, MacPherson, Duncan, Ballistic Publications, El Segundo, CA, 1994, p. 84.

Shots #3 and #4 bullet jackets separated from lead core and the jackets came to rest at 11.6" and 11.3", respectively. The separated lead cores penetrated completely through the 18" long gelatin block and were not recovered.

Penetration depth of shots #1, #2 and #5 corrected to 14.5", 14.9" and 15.4", respectively, in accordance with: MacPherson, Duncan: "A Simplified Penetration Depth Correction for Data Taken in Non-standard Gelatin." Wound Ballistics Review 2(2); pp. 41-45, 1995.

Five shot average penetration depth and expanded diameter cannot be determined because shots #3 and #4 penetrated entire length of 18 inch gelatin block, exited, and were not recovered.


Figure 1. Angular View, Nose Up

end of page bar.gif (913 bytes)

Delivering you informative multimedia essays about the "battlefield problem-solving" tactical aspects of armed self-defense.

Web Site Index and Navigation Center

Copyright © 1998 - 2002 Firearms Tactical Institute. All Rights Reserved.
FirearmsTactical™, Salus In Periculo, and logo are trademarks of Firearms Tactical Institute.